021 8690 6777 | 021 8690 6770
0812 9049 9480 | 0812 9595 7914 | 0812 8006 9024
0813 8742 8586 | 0878 7867 0721
0812 1470 6170 | 0813 1066 1358 | 0888 6129 511






 
Home   »   Produk   »   HOBO   »   Temperature Data Loggers & Sensor   »   Sensor
 
 

Telaire 7001 CO2 Sensor Sensor - TEL-7001

 
 
 

Untuk memesan, silahkan tekan tombol ORDER. Anda bisa memesan barang secara Online.

 

Anda juga bisa memesan via telephone, silakan hubungi sales consultant. Hotline kami di (021) 8690 6777 sales Consultant kami akan menjelaskan detail produk dan harga terbaru. atau email ke alamat sales@alatperaga.com

Telaire 7001 CO2 Sensor

The Telaire 7001 handheld carbon dioxide sensor features patented Absorption Infrared technology. Each sensor measures CO2 and temperature and can calculate and display real-time ventilation rates. When combined with the HOBO U12 or ZW Series it can record CO2, and when connected to an analog input on a H22, RX3000, or U30 Series it can record temperature and CO2. The Telaire comes with an adapter but also operates up to 70 hours on 4 AA batteries (not included). 

Environment:
The TEL-7001 Sensor is for use in Indoorenvironments

Measurements:
The TEL-7001 Sensor supports the following measurements:
Temperature • Carbon Dioxide

 

 

Features :

  • Record 0 to 2500 ppm when using the CABLE-CO2 and a U12 or ZW
  • Record 0 to 4000 ppm when using the CABLE-2070 and a H22 or U30
  • AC Power Adapter Included

Specification :

Measurement Range: 
0 to 2500 ppm when using the CABLE-CO2 and a U12 or ZW
0 to 4000 ppm when using the CABLE-2070 and a H22 or U30

Telaire 7001 Operating Range:
32°F to 122°F (0°C to 50°C), 0 to 95% RH, non-condensing

Display Resolution: ±1 ppm

Accuracy: ±50 ppm or 5% of reading, whichever is greater

Repeatability: ±20 ppm

Temperature Dependence: ±0.1% of reading per °C or ±2 ppm per °C, whichever is greater, referenced at 25°C.

Pressure Dependence: 0.13% of reading per mmHg (corrected via user input for elevation)

Response Time: <60 seconds for 90% of step change

Warm-Up Time: <60 seconds at 72°F (22°C)

Calibration Interval: 12 months Full factory calibration available by contacting GE Measurement & Control Solutions.
http://www.gesensinginspection.com/en/services-and-support.html

Battery Type: Four AA batteries (not included)

Battery Operation: 80 hours (alkaline)

External Power Supply Specifications:
AC/DC adapter (included)
Output: 6 VDC, 500mA output.
Power Connector: Round barrel with 2.5mm ID , 5.5mm OD, 12mm long, center positive (+6 VDC), outer shell ground.